I configured the snc conecction for SAP to connect to my server but the saprouter doesnu00B4t start, the log in the file dev_rout says
-
trc file: "dev_rout", trc level: 1, release: "700"
-
Mon Jul 31 13:58:02 2006
SAP Network Interface Router, Version 38.0
command line arg 0: G:\usr\sap\saprouter\saprouter.exe
command line arg 1: -r
command line arg 2: -S
command line arg 3: sapdp99
command line arg 4: -W
command line arg 5: 60000
command line arg 6: -R
command line arg 7: G:\usr\sap\saprouter\saprouttab
command line arg 8: -K
command line arg 9: CN=ramsapg01, OU=0000681331, OU=SAProuter, O=SAP, C=DE
command line arg 10: -G
command line arg 11: saprouter.log
SncInit(): Initializing Secure Network Communication (SNC)
PC with Windows NT (mt,ascii,SAP_UC/size_t/void* = 8/32/32)
SncInit(): Trying environment variable SNC_LIB as a
gssapi library name: "G:\usr\sap\saprouter\sapcrypto.dll".
File "G:\usr\sap\saprouter\sapcrypto.dll" dynamically loaded as GSS-API v2 library.
The internal Adapter for the loaded GSS-API mechanism identifies as:
Internal SNC-Adapter (Rev 1.0) to SECUDE 5/GSS-API v2
ERROR => SncPSetNewName()==SNCERR_BAD_NT_PREFIX [sncxxall.c 2200]
SncPImportPrName() parsing error
name="CN=ramsapg01, OU=0000681331, OU=SAProuter, O=SAP, C=DE"
<<- SncSetMyName()==SNCERR_BAD_NT_PREFIX
in: myname = "CN=ramsapg01, OU=0000681331, OU=SAProuter, O=SAP, C=DE"
ERROR => NiSncInit: SncSetMyNameU failed (rc=-35;'CN=ramsapg01, OU=0000681331, OU=SAProuter, O=SAP, C=DE') [nisnc.c 663]
ERROR => main: NiSncInit failed (rc=-17) [nirout.cpp 1214]
*****************************************************************************
*
ERROR SNC processing failed:
SncSetMyNameU
*
TIME Mon Jul 31 13:58:02 2006
RELEASE 700
COMPONENT NI (network interface)
VERSION 38
RC -17
MODULE nisnc.c
LINE 661
DETAIL NiSncInit: sncrc=-35
COUNTER 3
*